2012年9月18日 星期二

EVENT ID 2188 Storage Service



以下參考至:http://support.dell.com/support/edocs/software/svradmin/5.1/en/omss_ug/html/evntmntr.html
原文如下
Description: The controller write policy has been changed to Write Through.
Cause: The controller battery is unable to maintain cached data for the required period of time. For example, if the required period of time is 24 hours, then the battery is unable to maintain cached data for 24 hours. It is normal to receive this alert during the battery Learn cycle. This is because the Learn cycle discharges the battery before recharging it. When discharged, the battery cannot maintain cached data.

Action: Verify the health of the battery. If the battery is not healthy, then replace the battery pack.

Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.

Clear Alert Number: None.

SNMP Trap Number: 1153. See "SNMP Support for Storage Management Alerts" for more information.



GOOGLE翻釋如下:
說明:控制器寫入策略已更改為直寫。
原因:控制器電池是無法維持所需的一段時間內緩存的數據。例如,如果需要的時間週期是24小時,然後將電池是無法維持24小時的高速緩存的數據。在電池記憶週期,這是正常收到此警報。這是因為學習週期放電的電池充電之前。當放電後,電池不能維持高速緩存數據。

操作:驗證電池的健康。如果電池是不是健康的,然後更換電池組。

嚴重性:警告/不嚴重。有關更多信息,請參閱“警報嚴重級別”。

清除警報號:無。

SNMP陷阱號:1153。請參見“SNMP支持存儲管理的通知”的詳細信息。

沒有留言:

張貼留言